| 价格 | 111.00元 |
|---|---|
| 品牌 | 倍加福 |
| 区域 | 全国 |
| 来源 | 重庆派欧工业自动化控制设备有限公司 |
详情描述:
NJ4-12GK-SN原装倍加福传感器现货General specifications Switching function Normally closed (NC) Output type NAMUR with safety function Rated operating distance 4 mm Installation non-flush Assured operating distance 0 ... 3.24 mm Reduction factor rAl 0.4 Reduction factor rCu 0.3 Reduction factor r304 0.85 Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl Fuchs, such as KFD2-SH-EX1.
Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.Output type 2-wire Nominal ratings Nominal voltage 8.2 V Switching frequency 0 ... 1500 Hz Current consumption Measuring plate not detected ≥ 3 mA Measuring plate detected ≤ 1 mA Functional safety related parameters Safety Integrity Level (SIL) SIL 3 MTTFd 10660 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 % Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000
IEC 60947-5-6:1999Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012Approvals and certificates EAC conformity TR CU 012/2011 FM approval Control drawing 116-0165 UL approval cULus Listed, General Purpose CCC approval CCC approval / marking not required for products rated ≤36 V Ambient conditions Ambient temperature -50 ... 100 ?C (-58 ... 212 ?F)
Safety application: -40 ... 100?CMechanical specifications Connection type cable silicone , 2 m Core cross-section 0.34 mm2 Housing material Crastin (PBT), black Sensing face Crastin (PBT), black Degree of protection IP68 Cable Bending radius > 10 x cable diameter Note Security relevant only up to -40?C Data for application in connection with hazardous areas Equipment protection level Ga , Gb , Gc (ic) , Gc (nA) , Da , Dc , Mb Equipment protection level Ga Type of protection intrinsic safety CE marking [*PD-Z02585A*] Certificates Appropriate type NJ4-12GK-SN... ATEX certificate PTB 00 ATEX 2049 X ATEX marking
II 1G Ex ia IIC T6…T1 GaStandards EN 60079-0:2012 A11:2013 , EN 60079-11:2012 IECEx certificate IECEx PTB 11.0092X IECEx marking Ex ia IIC T6...T1 Ga Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance max. 70 nF
A cable length of 10 m is considered.Effective internal inductance max. 150 ?H
A cable length of 10 m is considered.Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.for ATEX at Ui = 16 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 57 ?C (134.6 ?F)
T5 : 69 ?C (156.2 ?F)
T4 : 97 ?C (206.6 ?F)
T3 : 97 ?C (206.6 ?F)
T2 : 97 ?C (206.6 ?F)
T1 : 97 ?C (206.6 ?F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 52 ?C (125.6 ?F)
T5 : 64 ?C (147.2 ?F)
T4 : 92 ?C (197.6 ?F)
T3 : 92 ?C (197.6 ?F)
T2 : 92 ?C (197.6 ?F)
T1 : 92 ?C (197.6 ?F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 34 ?C (93.2 ?F)
T5 : 46 ?C (114.8 ?F)
T4 : 74 ?C (165.2 ?F)
T3 : 74 ?C (165.2 ?F)
T2 : 74 ?C (165.2 ?F)
T1 : 74 ?C (165.2 ?F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW ,
T6 : 22 ?C (71.6 ?F)
T5 : 34 ?C (93.2 ?F)
T4 : 61 ?C (141.8 ?F)
T3 : 61 ?C (141.8 ?F)
T2 : 61 ?C (141.8 ?F)
T1 : 61 ?C (141.8 ?F)for IECEx at Ui = 16 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 73 ?C (163.4 ?F)
T5 : 88 ?C (190.4 ?F)
T4 : 100 ?C (212 ?F)
T3 : 100 ?C (212 ?F)
T2 : 100 ?C (212 ?F)
T1 : 100 ?C (212 ?F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 69 ?C (156.2 ?F)
T5 : 84 ?C (183.2 ?F)
T4 : 100 ?C (212 ?F)
T3 : 100 ?C (212 ?F)
T2 : 100 ?C (212 ?F)
T1 : 100 ?C (212 ?F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 51 ?C (123.8 ?F)
T5 : 66 ?C (150.8 ?F)
T4 : 80 ?C (176 ?F)
T3 : 80 ?C (176 ?F)
T2 : 80 ?C (176 ?F)
T1 : 80 ?C (176 ?F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW ,
T6 : 39 ?C (102.2 ?F)
T5 : 54 ?C (129.2 ?F)
T4 : 61 ?C (141.8 ?F)
T3 : 61 ?C (141.8 ?F)
T2 : 61 ?C (141.8 ?F)
T1 : 61 ?C (141.8 ?F)Equipment protection level Gb Type of protection intrinsic safety CE marking [*PD-Z02585A*] Certificates Appropriate type NJ4-12GK-SN... ATEX certificate PTB 00 ATEX 2049 X ATEX marking
II 1G Ex ia IIC T6…T1 GaStandards EN 60079-0:2012 A11:2013 , EN 60079-11:2012 IECEx certificate IECEx PTB 11.0092X IECEx marking Ex ia IIC T6...T1 Ga Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance max. 70 nF
A cable length of 10 m is considered.Effective internal inductance max. 150 ?H
A cable length of 10 m is considered.Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 73 ?C (163.4 ?F)
T5 : 88 ?C (190.4 ?F)
T4 : 100 ?C (212 ?F)
T3 : 100 ?C (212 ?F)
T2 : 100 ?C (212 ?F)
T1 : 100 ?C (212 ?F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 69 ?C (156.2 ?F)
T5 : 84 ?C (183.2 ?F)
T4 : 100 ?C (212 ?F)
T3 : 100 ?C (212 ?F)
T2 : 100 ?C (212 ?F)
T1 : 100 ?C (212 ?F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 51 ?C (123.8 ?F)
T5 : 66 ?C (150.8 ?F)
T4 : 80 ?C (176 ?F)
T3 : 80 ?C (176 ?F)
T2 : 80 ?C (176 ?F)
T1 : 80 ?C (176 ?F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW ,
T6 : 39 ?C (102.2 ?F)
T5 : 54 ?C (129.2 ?F)
T4 : 61 ?C (141.8 ?F)
T3 : 61 ?C (141.8 ?F)
T2 : 61 ?C (141.8 ?F)
T1 : 61 ?C (141.8 ?F)Equipment protection level Gc (ic) Type of protection intrinsic safety CE marking [*PD-Z02586A*] Certificates ATEX certificate PF 13 CERT 2895 X ATEX marking
II 3G Ex ic IIC T6…T1 GcStandards EN 60079-0:2012 A11:2013 , EN 60079-11:2012 Effective internal capacitance max. 70 nF
A cable length of 10 m is considered.Effective internal inductance max. 150 ?H
A cable length of 10 m is considered.Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 20 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 55 ?C (131 ?F)
T5 : 55 ?C (131 ?F)
T4 : 55 ?C (131 ?F)
T3 : 55 ?C (131 ?F)
T2 : 55 ?C (131 ?F)
T1 : 55 ?C (131 ?F)
at Ui = 20 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 55 ?C (131 ?F)
T5 : 55 ?C (131 ?F)
T4 : 55 ?C (131 ?F)
T3 : 55 ?C (131 ?F)
T2 : 55 ?C (131 ?F)
T1 : 55 ?C (131 ?F)
at Ui = 20 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 41 ?C (105.8 ?F)
T5 : 41 ?C (105.8 ?F)
T4 : 41 ?C (105.8 ?F)
T3 : 41 ?C (105.8 ?F)
T2 : 41 ?C (105.8 ?F)
T1 : 41 ?C (105.8 ?F)
at Ui = 20 V , Ii = 76 mA , Pi = 242 mW ,
T6 : 29 ?C (84.2 ?F)
T5 : 29 ?C (84.2 ?F)
T4 : 29 ?C (84.2 ?F)
T3 : 29 ?C (84.2 ?F)
T2 : 29 ?C (84.2 ?F)
T1 : 29 ?C (84.2 ?F)Equipment protection level Gc (nA) Type of protection "n" CE marking [*PD-Z02586A*] Certificates ATEX certificate PF 15 CERT 3754 X ATEX marking
II 3G Ex nA IIC T6 GcStandards EN 60079-0:2012 A11:2013 , EN 60079-15:2010 Possible characteristics maximum operating voltage UBmax , load current IL , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
using an amplifier in accordance with EN 60947-5-6 : 58 ?C (136.4 ?F)
at UBmax = 9 V , RV = 562 Ω : 58 ?C (136.4 ?F)Equipment protection level Da Type of protection intrinsic safety CE marking [*PD-Z02585A*] Certificates Appropriate type NJ4-12GK-SN... ATEX certificate PTB 00 ATEX 2049 X ATEX marking
II 1D Ex ia IIIC T135?C DaStandards EN 60079-0:2012 A11:2013 , EN 60079-11:2012 IECEx certificate IECEx PTB 11.0092X IECEx marking Ex ia IIIC T135?C Da Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance max. 70 nF
A cable length of 10 m is considered.Effective internal inductance max. 150 ?H
A cable length of 10 m is considered.Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 ?C (212 ?F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 ?C (212 ?F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 80 ?C (176 ?F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 61 ?C (141.8 ?F)Equipment protection level Dc Type of protection Protection by enclosure "tc" CE marking [*PD-Z02586A*] Certificates ATEX certificate PF 15 CERT 3774 X ATEX marking
II 3D Ex tc IIIC T80?C DcStandards EN 60079-0:2012 A11:2013, EN 60079-31:2014 Possible characteristics maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
using an amplifier in accordance with EN 60947-5-6 : 58 ?C (136.4 ?F)
at UBmax = 9 V , RV = 562 Ω : 58 ?C (136.4 ?F)Equipment protection level Mb Type of protection intrinsic safety Certificates Appropriate type NJ 4-12GK-SN... IECEx certificate IECEx PTB 11.0092X IECEx marking Ex ia I Mb Standards IEC 60079-0:2011 , IEC 60079-11:2011 Effective internal capacitance max. 70 nF
A cable length of 10 m is considered.Effective internal inductance max. 150 ?H
A cable length of 10 m is considered.Maximum permissible ambient temperature Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 ?C (212 ?F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 ?C (212 ?F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 80 ?C (176 ?F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 61 ?C (141.8 ?F)General information Use in the hazardous area see instruction manuals
| 联系人 | 秦艳 |
|---|